Non-computes and computes have different network interfaces, this page will talk about non-computes but in the context of a metal stack.

Name Type MTU
mgmt0 Slot 1 on the SMNET card. 9000
mgmt1 Slot 2 on the SMNET card, or slot 1 on the 2nd SMNET card. 9000
bond0 LACP Link Agg. of mgmt0 and mgmt1, or mgmt0 and mgmt2 on dual-bonds (when bond1 is present). 9000
bond1 LACP Link Agg. of mgmt1 and mgmt3. 9000
lan0 Externally facing interface. 1500
lan1 Yet-another externally facing interface, or anything (unused). 1500
hsn0 High-speed network interface. 9000
hsnN+1 Yet-another high-speed network interface. 9000
vlan002 Virtual LAN for managing nodes 1500
vlan004 Virtual LAN for managing hardware 1500
vlan007 Virtual LAN for the customer access network 1500

These interfaces can be observed on a live NCN (using ip link on the command line).

Device Naming / udev

The underlying naming relies on [BIOSDEVNAME][1], this helps conform device naming into a smaller set of possible names. It also helps show us when driver issues occur, if a non-BIOSDEVNAME interface appears then METAL can/should receive a triage report/bug.

MAC Based udev rules during initial boot in iPXE. When a node boots, iPXE will dump the PCI busses and sort network interfaces into 3 buckets:

  • mgmt: internal/management network connection
  • hsn: high-speed connection
  • lan: external/site-connection

The source code for the rule generation is in [metal-ipxe][1], but for technical information on the PCI configuration/reading please read on.

Vendor and Bus ID Identification

The initial boot of an NCN sets interface udev rules since it has no discovery method yet.

The information needed is:

  • PCI Vendor IDs for devices/cards to be used on the Management network.
  • PCI Device IDs for the devices/cards to be used on the High-Speed Network.

The 16-bit Vendor ID is allocated by the PCI-SIG (Peripheral Component Interconnect Special Interest Group).

PCI Configuration Space

The information belongs to the first 4 bytes of the PCI header, and admin can obtain it using lspci or your preferred method for reading the PCI bus.

Collection Example

lspci | grep -i ethernet
lspci | grep c6:00.0

These are commonly found in Cray computers.

The Device and Vendor IDs are used in iPXE for bootstrapping the nodes, this allows generators to swap IDs out for certain systems until smarter logic can be added to cloud-init.

Vendor Model Device ID Vendor ID
Intel Corporation Ethernet Connection X722 37d2 8086
Intel Corporation 82576 1526 8086
Mellanox Technologies ConnectX-4 1013 15b3
Mellanox Technologies ConnectX-5 1017 15b3
Giga-Byte Intel Corporation I350 1521 8086
QLogic Corporation FastLinQ QL41000 8070 1077