Cabling

HPE Hardware

HPE DL385

DL385

  • The OCP Slot is noted (number 7) in the image above.
    • This is the bottom middle slot to the left of the VGA port.
    • Ports are numbered left-to-right: the far left port is port 1.
  • The PCIe Slot 1 is on the top left side of the image above (under number 1).
    • Ports are numbered left-to-right: the far left port is port 1.

HPE DL325

DL325

  • The OCP Slot is noted (number 9) in the image above.
    • This is the slot on the bottom left of the node.
    • Ports are numbered left-to-right: the far left port is port 1.
  • The PCIE Slot 1 is on the top left side of the image above (under number 1).
    • Ports are numbered left-to-right: the far left port is port 1.

NCN Worker Cabling

Server Port Management Network Port Speed Use / Configuration
OCP port 1 spine or aggr pair, switch 1/2 25Gb Management Network NMN/HMN/CAN
OCP port 2 NONE NONE NONE
PCIe Slot 1 port 1 spine or aggr pair, switch 2/2 25Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 NONE NONE NONE

SHCD Example

hostname Source Destination Destination
wn01 x3000u04ocp-j1 x3000u12-j7 sw-25g01
wn01 x3000u04ocp-j2 x3000u13-j7 sw-25g02

HPE_Worker

NCN Master Cabling

Single Card Installations

Server Port Management Network Port Speed Use / Configuration
OCP port 1 spine or aggr pair, switch 1/2 25Gb Management Network NMN/HMN/CAN
OCP port 2 NONE NONE NONE
PCIe Slot 1 port 1 spine or aggr pair, switch 2/2 25Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 NONE (See note below for ncn-m001) NONE Site (See note below for ncn-m001)

Dual Card Installations

A dual card configuration is much less common, but can occur based on customer requirements. The table below describes the cabling of dual card configurations. Also read notes in this section to see other possible customer-based configurations.

Server Port Management Network Port Speed Use / Configuration
OCP port 1 spine or aggr pair, switch 1/2 25Gb Management Network NMN/HMN/CAN
OCP port 2 NONE NONE NONE
PCIe Slot 1 port 1 spine or aggr pair, switch 2/2 25Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 NONE (See note below for ncn-m001) NONE Site (See note below for ncn-m001)

SHCD Example

hostname Source Destination Destination
mn01 x3000u01ocp-j1 x3000u12-j1 sw-25g01
mn01 x3000u01s1-j1 x3000u13-j1 sw-25g02

HPE_Worker NOTE: Master 1 (ncn-m001) is required to have a site connection for installation and non-CAN system access. This can have several configurations depending on customer requirements/equipment:

  • Dual 10/25Gb card configurations as described in the table above should use PCIe Slot 1, Port 2 as a site connection if the customer supports 10/25Gb.
  • If the customer does not support 10/25Gb speeds (or connection type) and requires RJ45 copper or 1Gb, then a new and separate card will be installed on ncn-m001 and that card will provide site connectivity.
  • Another possibility (non-HPE hardware mainly) is that a built-in 1Gb port will be used if available (similar to Shasta v1.3 PoR on Gigabyte hardware).

NCN Storage Cabling

Server Port Management Network Port Speed Use / Configuration
OCP port 1 spine or aggr pair, switch 1/2 25Gb Management Network NMN/HMN/CAN
OCP port 2 spine or aggr pair, switch 1/2 25Gb Storage SUN (future use)
PCIe Slot 1 port 1 spine or aggr pair, switch 2/2 25Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 25Gb Storage SUN (future use)

SHCD Example

hostname Source Destination Destination
sn01 x3000u17s1-j2 x3000u34-j14 sw-25g02
sn01 x3000u17s1-j1 x3000u34-j8 sw-25g02
sn01 x3000u17ocp-j2 x3000u33-j14 sw-25g01
sn01 x3000u17ocp-j1 x3000u33-j8 sw-25g01

HPE_Storage

For systems that include 4 aggregation switches the cabling will look like the following.

HPE_Large_Storage

SHCD Example with four aggregation switches.

hostname Source Destination Destination
sn01 x3000u10ocp-j2 x3000u36-j5 sw-25g04
sn01 x3000u10s1-j2 x3000u35-j5 sw-25g03
sn01 x3000u10ocp-j1 x3000u34-j6 sw-25g02
sn01 x3000u10s1-j1 x3000u33-j6 sw-25g01

UAN Cabling

Server Port Management Network Port Speed Use / Configuration
OCP port 1 spine or aggr pair, switch 1/2 25Gb Management Network NMN
OCP port 2 spine or aggr pair, switch 1/2 25Gb Management Network CAN bond
PCIe Slot 1 port 1 spine or aggr pair, switch 2/2 25Gb NONE (Shasta v1.4)
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 25Gb Management Network CAN bond

SHCD Example

hostname Source Destination Destination
uan01 x3000u17s1-j2 x3000u34-j14 sw-25g02
uan01 x3000u17s1-j1 x3000u34-j8 sw-25g02
uan01 x3000u17ocp-j2 x3000u33-j14 sw-25g01
uan01 x3000u17ocp-j1 x3000u33-j8 sw-25g01

HPE_UAN

Gigabyte/Intel Hardware

NCN Worker Cabling

Gigabyte Worker

Server Port Management Network Port Speed Use / Configuration
PCIe Slot 1 port 1 spine or aggr pair, switch 1/2 40Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 40Gb Management Network NMN/HMN/CAN

SHCD Example

hostname Source Destination Destination
wn01 x3000u07s1-j1 x3000u24L-j4 sw-smn02
wn01 x3000u07s1-j2 x3000u24R-j4 sw-smn03

Gig_intel_worker

NOTE: Cabling of ncn-w001 has changed in Shasta v1.4. Please see ncn-m001 note below.

NCN Master Cabling

Gigabyte Master

Server Port Management Network Port Speed Use / Configuration
PCIe Slot 1 port 1 spine or aggr pair, switch 1/2 40Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 40Gb Management Network NMN/HMN/CAN
LAN0 port 1 NONE (See note below for ncn-m001) NONE Site (See note below for ncn-m001)

SHCD Example

hostname Source Destination Destination
mn01 x3000u01s1-j1 x3000u24L-j1 sw-smn02
mn01 x3000u01s1-j2 x3000u24R-j1 sw-smn03

Gig_intel_master

NOTE: Master 1 (ncn-m001) is required to have a site connection for installation and non-CAN system access. In Shasta versions <=1.3 this connection was on ncn-w001. This can have several configurations depending on customer requirements/equipment:

  • The default configuration for Gigabyte systems uses the built-in 1Gb lan0 port for site connection on ncn-m001.
  • If the customer requires connectivity greater than 1Gb (or a different connection type), then a new and separate card will be installed on ncn-m001 and that card will provide site connectivity.

NCN Storage Cabling

Gigabyte Storage

Server Port Management Network Port Speed Use / Configuration
PCIe Slot 1 port 1 spine or aggr pair, switch 1/2 40Gb Management Network NMN/HMN/CAN
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 40Gb Management Network NMN/HMN/CAN

SHCD Example

hostname Source Destination Destination
sn01 x3000u13s1-j1 x3000u24L-j7 sw-smn02
sn01 x3000u13s1-j2 x3000u24R-j7 sw-smn03

Gig_intel_storage

UAN Cabling

Server Port Management Network Port Speed Use / Configuration
LAN0 port 1 leaf (see note) 1Gb Management Network NMN
PCIe Slot 1 port 1 spine or aggr pair, switch 1/2 40Gb Management Network CAN bond
PCIe Slot 1 port 2 spine or aggr pair, switch 2/2 40Gb Management Network CAN bond

SHCD Example

hostname Source Destination Destination
uan01 x3000u27s1-j1 x3000u24L-j10 sw-smn02
uan01 x3000u27s1-j2 x3000u24R-j10 sw-smn03

Gig_intel_uan

NOTE that there are a couple configurations possible for LAN0:

  • Existing Gigabyte systems on Dell and Mellanox network hardware will use the (existing) Dell leaf port.
  • Any Gigabyte system on Aruba network hardware will use a Aruba 6300 (for the 1Gb port).
  • Optionally a 10/25Gb card could be added in an Aruba hardware system to match the HPE UANs.