This procedure will use the System Configuration Service (SCSD) to change all air-cooled Node BMCs in the system to the same global credential.
All air-cooled and liquid-cooled BMCs share the same global credentials. The air-cooled Slingshot switch controllers (Router BMCs) must have the same credentials as the liquid-cooled Slingshot switch controllers.
Set the NEW_BMC_CREDENTIAL
to specify the new root
user password for air-cooled node BMCs.
ncn-m001# read -s NEW_BMC_CREDENTIAL
ncn-m001# echo $NEW_BMC_CREDENTIAL
Expected output:
new.root.password
Create an SCSD payload file to change all air-cooled node BMCs to the same global credential.
ncn-m001# cat > bmc_creds_glb.json <<DATA
{
"Force":false,
"Username": "root",
"Password": "$NEW_BMC_CREDENTIAL",
"Targets":
$(cray hsm state components list --class River --type NodeBMC --format json | jq -r '[.Components[] | .ID]')
}
DATA
Inspect the generated SCSD payload file.
ncn-m001# cat bmc_creds_glb.json | jq
Apply the new BMC credentials.
ncn-m001# cray scsd bmc globalcreds create ./bmc_creds_glb.json
Troubleshooting: If the above command has any components that do not have the status of OK, they must be retried until they work, or the retries are exhausted and noted as failures. Failed modules need to be taken out of the system until they are fixed.