Apply the backed up site connection configuration with a couple modifications. Since virtual routing and forwarding (VRF) is now used to separate customer traffic, the site ports and default routes must be added to that VRF.
conf t
interface 1/1/36
no shutdown
description to:CANswitch_cfcanb6s1-31:from:sw-25g01_x3000u39-j36
ip address 10.101.15.142/30
exit
conf t
sw-spine-001(config)# system interface-group 3 speed 10g
conf t
interface 1/1/36
no shutdown
description to:CANswitch_cfcanb6s1-46:from:sw-25g02_x3000u40-j36
ip address 10.101.15.190/30
exit
If the switch had system interface-group
commands those would be added here.
sw-spine-001(config)# system interface-group 3 speed 10g
conf t
sw-spine-001(config)# ip route 0.0.0.0/0 10.101.15.141 vrf default
conf t
sw-spine-002(config)# ip route 0.0.0.0/0 10.101.15.189 vrf default
sw-spine-001 [mlag-domain: master] # conf t
interface ethernet 1/16 speed 10G force
interface ethernet 1/16 mtu 1500 force
interface ethernet 1/16 no switchport force
interface ethernet 1/16 ip address 10.102.255.10/30 primary
sw-spine-002 [mlag-domain: master] # conf t
interface ethernet 1/16 speed 10G force
interface ethernet 1/16 mtu 1500 force
interface ethernet 1/16 no switchport force
interface ethernet 1/16 ip address 10.102.255.86/30 primary
sw-spine-001 [mlag-domain: master] # conf t
ip route vrf default 0.0.0.0/0 10.102.255.9
sw-spine-002 [mlag-domain: master] # conf t
ip route vrf default 0.0.0.0/0 10.102.255.85
All that is required to re-apply the users is to get into global configuration mode with conf t
and to paste in the configuration that was copied from the previous step.
conf t
user admin group administrators password ciphertext xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
conf t
system-user linuxadmin password xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
username admin password xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx role sysadmin priv-lvl 15
sw-spine-001 [standalone: master] # conf t
username admin password 7 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
username monitor password 7 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
conf t
snmp-server group cray-reds-group 3 noauth read cray-reds-view
snmp-server user testuser cray-reds-group 3 auth md5 xxxxxxxx priv des xxxxxxx
snmp-server view cray-reds-view 1.3.6.1.2 included
conf t
snmp-server vrf default
snmpv3 user testuser auth md5 auth-pass plaintext xxxxxx priv des priv-pass plaintext xxxxx
For more information on SNMP credentials, see Change SNMP Credentials on Leaf-BMC Switches and Update Default Air-Cooled BMC and Leaf-BMC Switch SNMP Credentials
Save the configuration once the configuration is applied. See Saving Configuration.