This topic describes nodes in the air-cooled cabinet with diagrams and pictures showing where to find the ports on the nodes and how to cable the nodes to the management network switches.


| Device | Port | Linux Device | Destination | Name | VLAN | LAG |
|---|---|---|---|---|---|---|
| OCP | 1 | mgmt0 |
primary | N/A | HMN, NMN, CAN | MLAG-LACP |
| OCP | 2 | mgmt1 |
secondary | N/A | HMN, NMN, CAN | MLAG-LACP |
| ILO | 1 | None | HMN leaf-bmc |
N/A | HMN | N/A |
NOTES:
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
wn01 |
x3000u04ocp-j1 |
x3000u12-j7 |
sw-25g01 |
wn01 |
x3000u04ocp-j2 |
x3000u13-j7 |
sw-25g02 |

The table below describes the cabling of dual card configurations. Also read notes in this section to see other possible customer-based configurations.
| Device | Port | Linux Device | Destination | Name | VLAN | LAG |
|---|---|---|---|---|---|---|
| OCP | 1 | mgmt0 |
primary | N/A | HMN, NMN, CAN | MLAG-LACP |
| OCP | 2 | N/A | N/A | N/A | N/A | N/A |
| PCIe Slot 1 | 1 | mgmt1 |
secondary | N/A | HMN, NMN, CAN | MLAG-LACP |
| PCIe Slot 1 | 2 | N/A | N/A | N/A | N/A | N/A |
| ILO | 1 | None | HMN leaf-bmc |
N/A | HMN | N/A |
NOTES:
ncn-m001) is required to have a site connection on OCP Port 2 for installation and
maintenance.ncn-m001) is required to have its BMC/iLO connected to the site.SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
mn01 |
x3000u01ocp-j1 |
x3000u12-j1 |
sw-25g01 |
mn01 |
x3000u01s1-j1 |
x3000u13-j1 |
sw-25g02 |

NOTE: Master 1 (ncn-m001) is required to have a site connection for installation and non-CAN system access. This can have several configurations depending on customer requirements/equipment:
10/25Gb card configurations as described in the table above should use PCIe Slot 1, Port 2 as a site connection
if the customer supports 10/25Gb.10/25Gb speeds (or connection type) and requires RJ45 copper or 1Gb, then a new
and separate card will be installed on ncn-m001 and that card will provide site connectivity.1Gb port will be used if available (similar to
CSM v1.3 PoR on Gigabyte hardware).| Device | Port | Linux Device | Destination | Name | VLAN | LAG |
|---|---|---|---|---|---|---|
| OCP | 1 | mgmt0 |
primary | N/A | HMN, NMN, CAN | MLAG-LACP |
| OCP | 2 | sun1 |
primary | N/A | SUN | MLAG-LACP |
| PCIe Slot 1 | 1 | mgmt1 |
secondary | N/A | HMN, NMN, CAN | MLAG-LACP |
| PCIe Slot 1 | 2 | sun1 |
secondary | N/A | SUN | MLAG-LACP |
| ILO | 1 | None | HMN leaf-bmc |
N/A | HMN | N/A |
NOTES:
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
sn01 |
x3000u17s1-j2 |
x3000u34-j14 |
sw-25g02 |
sn01 |
x3000u17s1-j1 |
x3000u34-j8 |
sw-25g02 |
sn01 |
x3000u17ocp-j2 |
x3000u33-j14 |
sw-25g01 |
sn01 |
x3000u17ocp-j1 |
x3000u33-j8 |
sw-25g01 |
The OCP ports go to the First switch and the PCIe ports go to the Second switch. OCP port 1 and PCIe port 1 form a Bond. OCP port 2 and PCIe port 2 form a Bond.

For systems that include 4 leaf switches the cabling will look like the following.

SHCD Example with four leaf switches.
| hostname | Source | Destination | Destination |
|---|---|---|---|
sn01 |
x3000u10ocp-j2 |
x3000u36-j5 |
sw-25g04 |
sn01 |
x3000u10s1-j2 |
x3000u35-j5 |
sw-25g03 |
sn01 |
x3000u10ocp-j1 |
x3000u34-j6 |
sw-25g02 |
sn01 |
x3000u10s1-j1 |
x3000u33-j6 |
sw-25g01 |
| Device | Port | Linux Device | Destination | Name | VLAN | LAG |
|---|---|---|---|---|---|---|
| OCP | 1 | nmn0 |
primary | N/A | NMN | N/A |
| OCP | 2 | net3 |
primary | N/A | CAN | MLAG-LACP |
| PCIe Slot 1 | 1 | net0 |
secondary | N/A | N/A | N/A |
| PCIe Slot 1 | 2 | net1 |
secondary | N/A | CAN | MLAG-LACP |
| ILO | 1 | None | HMN leaf-bmc |
N/A | HMN | N/A |
NOTES:
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
uan01 |
x3000u17s1-j2 |
x3000u34-j14 |
sw-25g02 |
uan01 |
x3000u17s1-j1 |
x3000u34-j8 |
sw-25g02 |
uan01 |
x3000u17ocp-j2 |
x3000u33-j14 |
sw-25g01 |
uan01 |
x3000u17ocp-j1 |
x3000u33-j8 |
sw-25g01 |


| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| OCP port 1 | 1G leaf-bmc switch |
1Gb |
Management Network NMN |
| OCP port 2 | None | None | None |
| OCP port 3 | None | None | None |
| OCP port 4 | None | None | None |
| iLO | 1G leaf-bmc switch |
1Gb |
Management Network HMN |

1Gb management network card and one
will be for the HSN.| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| PCIe port 1 | 1G leaf-bmc switch |
1Gb |
Management Network NMN |
| PCIe port 2 | None | None | None |
| PCIe port 3 | None | None | None |
| PCIe port 4 | None | None | None |
| iLO | 1G leaf-bmc switch |
1Gb |
Management Network HMN |

| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| PCIe Slot 1 port 1 | spine or leaf pair, switch 1/2 | 40Gb |
Management Network NMN/HMN/CAN |
| PCIe Slot 1 port 2 | spine or leaf pair, switch 2/2 | 40Gb |
Management Network NMN/HMN/CAN |
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
wn01 |
x3000u07s1-j1 |
x3000u24L-j4 |
sw-smn02 |
wn01 |
x3000u07s1-j2 |
x3000u24R-j4 |
sw-smn03 |

NOTE: Cabling ofncn-w001has changed in CSM 1.4. Please seencn-m001note below.

| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| PCIe Slot 1 port 1 | spine or leaf pair, switch 1/2 | 40Gb |
Management Network NMN/HMN/CAN |
| PCIe Slot 1 port 2 | spine or leaf pair, switch 2/2 | 40Gb |
Management Network NMN/HMN/CAN |
| LAN0 port 1 | NONE (See note below for ncn-m001) |
NONE | Site (See note below for ncn-m001) |
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
mn01 |
x3000u01s1-j1 |
x3000u24L-j1 |
sw-smn02 |
mn01 |
x3000u01s1-j2 |
x3000u24R-j1 |
sw-smn03 |

NOTE: Master 1 (ncn-m001) is required to have a site connection for installation and non-CAN system access. In CSM versions <=1.3 this connection was onncn-w001. This can have several configurations depending on customer requirements/equipment:
1Gb lan0 port for site connection on ncn-m001.1Gb (or a different connection type), then a new and separate
card will be installed on ncn-m001 and that card will provide site connectivity.
| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| PCIe Slot 1 port 1 | spine or leaf pair, switch 1/2 | 40Gb |
Management Network NMN/HMN/CAN |
| PCIe Slot 1 port 2 | spine or leaf pair, switch 2/2 | 40Gb |
Management Network NMN/HMN/CAN |
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
sn01 |
x3000u13s1-j1 |
x3000u24L-j7 |
sw-smn02 |
sn01 |
x3000u13s1-j2 |
x3000u24R-j7 |
sw-smn03 |

| Server Port | Management Network Port | Speed | Use / Configuration |
|---|---|---|---|
| LAN0 port 1 | leaf-bmc (see note) |
1Gb |
Management Network NMN |
| PCIe Slot 1 port 1 | spine or leaf pair, switch 1/2 | 40Gb |
Management Network CAN bond |
| PCIe Slot 1 port 2 | spine or leaf pair, switch 2/2 | 40Gb |
Management Network CAN bond |
SHCD Example
| hostname | Source | Destination | Destination |
|---|---|---|---|
uan01 |
x3000u27s1-j1 |
x3000u24L-j10 |
sw-smn02 |
uan01 |
x3000u27s1-j2 |
x3000u24R-j10 |
sw-smn03 |

NOTE that there are a couple configurations possible for LAN0:
leaf-bmc port.1Gb port).10/25Gb card could be added in an Aruba hardware system to match the HPE UANs.