Prepare the System for Power Off

This procedure prepares the system to remove power from all system cabinets. Be sure the system is healthy and ready to be shut down and powered off.

The sat bootsys shutdown and sat bootsys boot commands are used to shut down the system.

Prerequisites

An authentication token is required to access the API gateway and to use the sat command. See the “SAT Authentication” section of the HPE Cray EX System Admin Toolkit (SAT) product stream documentation (S-8031) for instructions on how to acquire a SAT authentication token.

Procedure

Collect authentication credentials and authenticate SAT

  1. Obtain the user ID and passwords for system components:

    1. Obtain user ID and passwords for all the system management network switches.

    2. If necessary, obtain the user ID and password for the ClusterStor primary management node. For example, cls01053n00.

    3. If the Slingshot network includes edge switches, obtain the user ID and password for these switches.

  2. Use sat auth to authenticate to the API gateway within SAT.

    If SAT has already been authenticated to the API gateway, this step may be skipped.

    See the “SAT Authentication” section in the HPE Cray EX System Admin Toolkit (SAT) product stream documentation (S-8031) for instructions on how to acquire a SAT authentication token.

Check shell initialization scripts

  1. Ensure /root/.bashrc has proper handling of kubectl commands on all master and worker nodes.

    Important: During the process of shutting down the system, there will be a point when kubelet will be stopped on all the master and worker nodes. Once kubelet has been stopped, any kubectl command on any master or worker node may not work as expected and may have a long timeout before failing.

    This issue can cause a slowdown for these sat commands which ssh from the sat pod to ncn-m001 and the other nodes because the ssh will execute commands from /root/.bashrc.

    • Commands affected during the power down

      • sat bootsys shutdown --stage platform-services
      • sat bootsys shutdown --stage ncn-power
    • Commands affected during the power up

      • sat bootsys boot --stage ncn-power
      • sat bootsys boot --stage platform-services
    1. Here is a sample command in /root/.bashrc which sets an environment variable using the output from kubectl which has the problem.

      export DOMAIN=$(kubectl get secret site-init -n loftsman -o jsonpath='{.data.customizations\.yaml}'|base64 -d | grep "external:")
      
    2. This shows one way to correct that sample command so the environment variable will be set when kubelet is available and will skip setting the variable when kubelet is not available.

      if systemctl is-active -q kubelet ; then
              export DOMAIN=$(kubectl get secret site-init -n loftsman -o jsonpath='{.data.customizations\.yaml}'|base64 -d | grep "external:")
      fi
      

Check SSH known hosts

  1. Ensure /root/.ssh/known_hosts does not have ssh stale host key entries for any of the management nodes.

    Important: Many of the sat commands use ssh from a sat Kubernetes pod to execute commands on the management nodes. This sat pod uses the paramiko Python library for ssh and it will access /root/.ssh/known_hosts. If /root/.ssh/config or /etc/ssh/config has been configured to set UserKnownHostsfile to /dev/null or some other file and there are ssh host key mismatches in /root/.ssh/known_hosts, then when a sat command tries to use ssh with paramiko, it will fail even though an interactive ssh command by the root user might succeed.

    For example, the sat bootsys shutdown --stage platform-services command would show this type of error and fail.

    INFO: Executing step: Stop and disable kubelet on all Kubernetes NCNs.
    ERROR: Host key for server 'ncn-w003' does not match: got 'AAAAE2VjZHNhLXNoYTItbmlzdHAyNTYAAAAIbmlzdHAyNTYAAABBBCGNgIUTU7+o/+c5bD84u7/1S3xNNOd5+c/0l4vpVEehWGrjuC6IRC/KAImozzznXHhdBL7yQF2Dnh3FHGQDyko=', expected 'AAAAE2VjZHNhLXNoYTItbmlzdHAyNTYAAAAIbmlzdHAyNTYAAABBBL9bwo5gmW/vX3kUQyXIDgJa4EVtCYDyntmNt43BHTM7YKn6yFe1dV59Ervi13V20OxdVECxg2hTyeTueVKvwj4='
    ERROR: Fatal error in step "Stop and disable kubelet on all Kubernetes NCNs." of platform services stop: Failed to ensure kubelet is inactive and disabled on all hosts.
    

    To prevent this issue from happening, remove stale ssh host keys from /root/.ssh/known_hosts before running the sat command.

Check certificate expiration deadlines

  1. Check certificate expiration deadlines to ensure that a certificate will not expire while the system is powered off.

    1. (ncn-mw#) Check the expiration date of the Spire Intermediate CA Certificate.

      kubectl get secret -n spire spire.spire.ca-tls -o json | jq -r '.data."tls.crt" | @base64d' | openssl x509 -noout -enddate
      

      Example output:

      notAfter=Dec 17 00:00:24 2024 GMT
      

      If the certificate will expire while the system is powered off, replace it before powering off the system. See Replace the Spire Intermediate CA Certificate.

    2. (ncn-m#) Check the Kubernetes and Bare Metal etcd certificates from a master node.

      Check certificate expiration deadlines for Kubernetes and its bare-metal etcd cluster.

      kubeadm certs check-expiration --config /etc/kubernetes/kubeadmcfg.yaml
      

      Example output:

      WARNING: kubeadm cannot validate component configs for API groups [kubelet.config.k8s.io kubeproxy.config.k8s.io]
      
      CERTIFICATE                EXPIRES                  RESIDUAL TIME   CERTIFICATE AUTHORITY   EXTERNALLY MANAGED
      admin.conf                 Sep 24, 2021 15:21 UTC   14d             ca                      no
      apiserver                  Sep 24, 2021 15:21 UTC   14d             ca                      no
      apiserver-etcd-client      Sep 24, 2021 15:20 UTC   14d             etcd-ca                 no
      apiserver-kubelet-client   Sep 24, 2021 15:21 UTC   14d             ca                      no
      controller-manager.conf    Sep 24, 2021 15:21 UTC   14d             ca                      no
      etcd-healthcheck-client    Sep 24, 2021 15:19 UTC   14d             etcd-ca                 no
      etcd-peer                  Sep 24, 2021 15:19 UTC   14d             etcd-ca                 no
      etcd-server                Sep 24, 2021 15:19 UTC   14d             etcd-ca                 no
      front-proxy-client         Sep 24, 2021 15:21 UTC   14d             front-proxy-ca          no
      scheduler.conf             Sep 24, 2021 15:21 UTC   14d             ca                      no
      
      CERTIFICATE AUTHORITY   EXPIRES                  RESIDUAL TIME   EXTERNALLY MANAGED
      ca                      Sep 02, 2030 15:21 UTC   8y              no
      etcd-ca                 Sep 02, 2030 15:19 UTC   8y              no
      front-proxy-ca          Sep 02, 2030 15:21 UTC   8y              no
      

      Depending on which certificates will expire, one of these procedures could be used for the renewal. The first procedure will renew all certificates, but that may be more than needs to be renewed.

    3. (ncn-m#) Check the kube-etcdbackup-etcd certificate expiration.

      kubectl get secret -n kube-system kube-etcdbackup-etcd -o json | jq -r '.data."tls.crt" | @base64d' | openssl x509 -noout -enddate
      

      Example output:

      notAfter=Apr 17 09:37:52 2025 GMT
      

      If the certificate has expired or will expire while the system is powered off, see the procedure steps for changing the kube-etcdbackup-etcd secret and then restarting Prometheus after the change.

    4. (ncn-m#) Check the etcd-ca certificate expiration.

      kubectl get secret -n sysmgmt-health etcd-client-cert -o json | jq -r '.data."etcd-ca" | @base64d' | openssl x509 -noout -enddate
      

      Example output:

      notAfter=Jan 13 18:01:48 2033 GMT
      

      If the etcd-ca certificate has expired or will expire while the system is powered off, see the procedure steps for changing the etcd-client-cert secret and then restarting Prometheus after the change.

    5. (ncn-m#) Check the etcd-client certificate expiration.

      kubectl get secret -n sysmgmt-health etcd-client-cert -o json | jq -r '.data."etcd-client" | @base64d' | openssl x509 -noout -enddate
      

      Example output:

      notAfter=Jan 16 18:01:49 2024 GMT
      

      If either the etcd-client certificate has expired or will expire while the system is powered off, see the procedure steps for changing the etcd-client-cert secret and then restarting Prometheus after the change.

Check Nexus backup status

  1. (ncn-mw#) Check for a recent backup of Nexus data.

    Note: Doing the Nexus backup may take multiple hours with Nexus being unavailable for the entire time.

    Check whether an export PVC called nexus-bak exists and is recent.

    kubectl get pvc -n nexus
    

    Example output:

    NAME         STATUS   VOLUME                                     CAPACITY   ACCESS MODES   STORAGECLASS           AGE
    nexus-bak    Bound    pvc-09b6efe6-18e3-4681-8103-53590ad49d04   1000Gi     RWO            k8s-block-replicated   293d
    nexus-data   Bound    pvc-bce9db69-d1a6-491d-89fc-d458c92f2895   1000Gi     RWX            ceph-cephfs-external   518d
    

    This output shows that the nexus-bak PVC was created 293 days ago.

    • If there is no nexus-bak PVC, then use this Nexus export procedure to create one. This procedure does check that there is enough space available for the copy of the nexus-data PVC and provides guidance on how to clean up space if necessary or reduce the size of the existing nexus-data PVC. See Nexus Export.

    • If there is an existing nexus-bak PVC, but it is too old or the age is not recent enough to include the most recent software update or otherwise not considered valid, then use the Nexus cleanup procedure before the export procedure. See Nexus Cleanup, then see Nexus Export.

Identify BOS session templates for managed nodes

  1. (ncn-mw#) Determine which Boot Orchestration Service (BOS) templates to use to shut down compute nodes and UANs.

    There will be separate session templates for UANs and computes nodes.

    1. List all the BOS session templates.

      If it is unclear what BOS session template is in use, proceed to the next substep.

      cray bos sessiontemplates list --format json | jq -r '.[].name' | sort
      
    2. Find the BOS session templates used most recently to boot nodes.

      sat status --filter role!=management --fields xname,role,subrole,"most recent session template"
      

      Example output:

      +----------------+-------------+-----------+------------------------------+
      | xname          | Role        | SubRole   | Most Recent Session Template |
      +----------------+-------------+-----------+------------------------------+
      | x3209c0s13b0n0 | Application | UAN       | uan-23.7.0                   |
      | x3209c0s15b0n0 | Application | UAN       | uan-23.7.0                   |
      | x3209c0s17b0n0 | Application | UAN       | uan-23.7.0                   |
      | x3209c0s19b0n0 | Application | UAN       | uan-23.7.0                   |
      | x3209c0s22b0n0 | Application | Gateway   | MISSING                      |
      | x3209c0s23b0n0 | Application | Gateway   | MISSING                      |
      | x9002c1s0b0n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s0b0n1  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s0b1n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s0b1n1  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s1b0n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s1b0n1  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s1b1n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s1b1n1  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s2b0n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s2b0n1  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s2b1n0  | Compute     | Compute   | compute-23.7.0               |
      | x9002c1s2b1n1  | Compute     | Compute   | compute-23.7.0               |
      +----------------+-------------+-----------+------------------------------+
      

      NOTE When the Most Recent Session Template shows MISSING, it means the BOS session information was removed. Old BOS sessions are cleaned up based on the numbers of days in cleanup_completed_session_ttl. The default value is seven days.

      1. Check the current setting for cleanup_completed_session_ttl.

        cray bos options list | grep cleanup_completed_session_ttl
        
    3. Determine the list of xnames associated with the desired boot session template.

      cray bos sessiontemplates describe SESSION_TEMPLATE_NAME --format json | jq '.boot_sets | map({node_list, node_roles_groups, node_groups})'
      

      Example outputs:

      [
        {
          "node_list": [
            "x3000c0s19b1n0",
            "x3000c0s19b2n0",
            "x3000c0s19b3n0",
            "x3000c0s19b4n0"
          ],
          "node_roles_groups": null,
          "node_groups": null
        }
      ]
      
      [
        {
          "node_list": null,
          "node_roles_groups": [
            "Compute"
          ],
          "node_groups": null
        }
      ]
      
  2. Confirm that the set of identified BOS session templates will affect all managed nodes in the system. This is important to ensure all managed nodes are gracefully shut down during the system power off.

Capture state and perform system health checks

  1. (ncn-mw#) Use SAT to capture state of the system before the shutdown.

    sat bootsys shutdown --stage capture-state
    
  2. (ncn-mw#) Optional system health checks.

    1. Use the System Diagnostic Utility (SDU) to capture current state of system before the shutdown.

      Important: SDU may take about 45 minutes to run on a small system (longer for large systems).

      sdu --scenario triage --start_time '-4 hours' \
               --reason "saving state before powerdown"
      
    2. Capture the state of all nodes.

      sat status | tee -a sat.status
      
    3. Capture the list of disabled nodes.

      sat status --filter Enabled=false | tee -a sat.status.disabled
      
    4. Capture the list of nodes that are off.

      sat status --filter State=Off | tee -a sat.status.off
      
    5. Capture the state of nodes in the workload manager.

      For example, if the system uses Slurm:

      ssh uan01 sinfo | tee -a uan01.sinfo
      ssh uan01 sinfo --list-reasons | tee -a sinfo.reasons
      

      For example, if the system uses PBS Pro:

      ssh uan01 pbsnodes -aS | tee -a pbsnodes.aS
      
    6. Check Ceph status.

      ceph -s | tee -a ceph.status
      
    7. Check Kubernetes pod status for all pods.

      kubectl get pods -o wide -A | tee -a k8s.pods
      

      Additional Kubernetes status check examples:

      kubectl get pods -o wide -A | egrep "CrashLoopBackOff" | tee -a k8s.pods.CLBO
      kubectl get pods -o wide -A | egrep "ContainerCreating" | tee -a k8s.pods.CC
      kubectl get pods -o wide -A | egrep -v "Run|Completed" | tee -a k8s.pods.errors
      
    8. Check HSN status.

      Run fmn-show-status in the slingshot-fabric-manager pod and save the output to a file.

      kubectl exec -it -n services \
          "$(kubectl get pod -l app.kubernetes.io/name=slingshot-fabric-manager
          -n services --no-headers | head -1 | awk '{print $1}')" \
           -c slingshot-fabric-manager -- fmn-show-status --details \
         | tee -a fmn-show-status-details.txt
      
    9. Check management switches to verify they are reachable.

      Note: The switch host names depend on the system configuration.

      1. (ncn-mw#) Use CANU to confirm that all switches are reachable. Reachable switches have their version information populated in the network version report.

        Provide the password for the admin username on the management network switches.

        canu report network version
        

        Example output:

        SWITCH            CANU VERSION      CSM VERSION
        sw-spine-001      1.7.1.post1       1.5
        sw-spine-002      1.7.1.post1       1.5
        sw-leaf-bmc-001   1.7.1.post1       1.5
        sw-leaf-bmc-002   1.7.1.post1       1.5
        sw-cdu-001        1.7.1.post1       1.5
        sw-cdu-002        1.7.1.post1       1.5
        
      2. (Optional) (ncn-mw#) If CANU is not available, look in /etc/hosts for the management network switches on this system. The names of all spine switches, leaf switches, leaf BMC switches, and CDU switches need to be used in the next step.

        grep 'sw-' /etc/hosts
        

        Example output:

        10.254.0.2      sw-spine-001
        10.254.0.3      sw-spine-002
        10.254.0.4      sw-leaf-bmc-001
        10.254.0.5      sw-leaf-bmc-002
        10.100.0.2      sw-cdu-001
        10.100.0.3      sw-cdu-002
        
      3. (ncn-mw#) Ping the switches obtained in the previous step to determine if they are reachable.

        for switch in $(awk '{print $2}' /etc/hosts | grep 'sw-'); do
            echo -n "switch ${switch} is "
            ping -c 1 -W 10 $switch > /dev/null && echo "up" || echo "not up"
        done | tee -a switches
        
    10. (ncn-mw#) Check Lustre server health. See Lustre documentation for other health commands to run.

      ssh admin@cls01234n00.us.cray.com
      cscli csinfo
      cscli show_nodes
      cscli fs_info
      
    11. From a node which has the Lustre file system mounted.

      lfs check servers
      lfs df
      

Check system activity

  1. (ncn-mw#) Check for running sessions.

    sat bootsys shutdown --stage session-checks 2>&1 | tee -a sat.session-checks
    

    Example output:

    Checking for active BOS sessions.
    Found no active BOS sessions.
    Checking for active CFS sessions.
    Found no active CFS sessions.
    Checking for active FAS actions.
    Found no active FAS actions.
    Checking for active NMD dumps.
    Found no active NMD dumps.
    Checking for active SDU sessions.
    Found no active SDU sessions.
    No active sessions exist. It is safe to proceed with the shutdown procedure.
    

    If active sessions are running, either wait for them to complete or cancel the session. See the following step.

    NOTE If the System Diagnostic Utility (SDU) has not been configured on master nodes, message like this will appear for the master nodes which are not configured for SDU. If the warning appears for all master nodes, then to enable this after the system has been powered up again, see the Configure section of the HPE Cray EX with CSM System Diagnostic Utility (SDU) Installation Guide to configure SDU and the optional RDA.

    WARNING: The cray-sdu-rda container is not running on ncn-m001.
    WARNING: The cray-sdu-rda container is not running on ncn-m002.
    WARNING: The cray-sdu-rda container is not running on ncn-m003.
    
  2. (ncn-mw#) Cancel the running BOS sessions.

    1. Identify the BOS sessions to delete.

      cray bos sessions list --format json
      
    2. Delete each running BOS session.

      cray bos sessions delete <session ID>
      

      Example:

      cray bos sessions delete 0216d2d9-b2bc-41b0-960d-165d2af7a742
      
  3. Coordinate with the site system administrators to prevent new sessions from starting in the services listed.

    There is no method to prevent new sessions from being created as long as the service APIs are accessible on the API gateway.

Notify people of upcoming power off

  1. Notify users and operations staff about the upcoming full system power off.

    The notification method will vary by system, but might be email, messaging applications, /etc/motd on UANs, wall commands on UANs, and so on.

Prepare workload managers

  1. Follow the vendor workload manager documentation to drain processes running on compute nodes.

    1. For Slurm, see the scontrol man page.

      The following are examples of how to drain nodes using slurm. The list of nodes can be copy/pasted from the sinfo command for nodes in an idle state:

      scontrol update NodeName=nid[001001-001003,001005] State=DRAIN Reason="Shutdown"
      
      scontrol update NodeName=ALL State=DRAIN Reason="Shutdown"
      
    2. For PBS Professional, see the qstat and qmgr man pages.

      The following is an example to list the available queues, disable a specific queue named workq, and check that the queue has been disabled:

      qstat -q
      qmgr -c 'set queue workq enabled = False'
      qmgr -c 'list queue workq enabled'
      

      Each system might have many different queue names. There is no default queue name.

Next step

Return to System Power Off Procedures and continue with next step.