Because of various hardware or communication issues, the node state reported by SAT and HSM (Hardware State Manager) may
become out of sync with the actual hardware state reported by PCS/CAPMC or Redfish. In most cases this will be noticed
when trying to power on or off nodes with BOS/BOA, and will present as SAT or HSM reporting nodes are On
while PCS/CAPMC
reports them as Off
(or vice versa).
Possible reasons the power state got out of sync include but are not limited to:
cray-hms-hmcollector
pod.In most cases, once the underlying cause has been corrected, this should correct itself when the node boots OS, starts
heartbeating, and goes to the Ready
state. If not, the power state for the affected nodes can be re-synced by kicking
off HSM re-discovery of those nodes’ BMCs.
cray hsm inventory discover create --xnames <list_of_BMC_xnames>
For example:
cray hsm inventory discover create --xnames x3000c0s0b0,x3000c0s1b0
The power state will be re-synced after all of the BMCs listed have a LastDiscoveryStatus
of DiscoverOK
.
cray hsm inventory redfishEndpoints describe x3000c0s0b0
Example output:
{
"ID": "x3000c0s0b0",
"Type": "NodeBMC",
"Hostname": "",
"Domain": "",
"FQDN": "x3000c0s0b0",
"Enabled": true,
"UUID": "808cde6e-debf-0010-e603-b42e993b708c",
"User": "root",
"Password": "",
"RediscoverOnUpdate": true,
"DiscoveryInfo": {
"LastDiscoveryAttempt": "2021-08-12T16:00:56.937774Z",
"LastDiscoveryStatus": "DiscoverOK",
"RedfishVersion": "1.7.0"
}
}
Any power operations done manually with PCS/CAPMC that alter the nodes’ power state may also cause the power state to re-sync.