CSM 1.5.1 Patch Installation Instructions

Introduction

This document guides an administrator through the patch update to Cray Systems Management v1.5.1 from CSM v1.5.0. If upgrading from CSM v1.4.x, then follow the procedures described in CSM major/minor version upgrade instead. In the unusual situation of upgrading from a pre-release version of CSM v1.5.0, then follow the procedures described in CSM major/minor version upgrade instead.

If there are more recent CSM v1.5 patch versions available, note that there is no need to perform intermediate CSM v1.5 patch upgrades. Instead, consider upgrading to the latest CSM v1.5 patch release. See CSM patch version upgrade for the full list of patch versions.

Bug fixes and improvements

  • Updated IMS to allow for remote node builds
  • Fixed an issue where hms-discovery would put default credentials into vault disabling non default credentials
  • Fixed an issue where cray-ipxe generated scripts would cause boot errors
  • Fixed an issue where BOS v2 would send large queries to CFS resulting 503 and 431 responses
  • Fixed an issue where PCS was adding invalid components to power operations
  • Fixed an issue where IUF would encounter a race condition and stall on transitioning to new stages
  • Fixed an issue where Thanos service is configured without storage limits
  • Fixed an issue where cray-dns-unbound-manager stderr handling can corrupt configuration
  • Fixed an issue where SAT status unnecessarily queries BOS for session template for every component
  • Fixed an issue where a PATCH to a BOS v2 session to change its name results in a bad state
  • Updated cray-hms-rts-init job to include a TTL
  • Updated node-exporter configuration to monitor SNMP counters
  • Updated documentation to cover switch configuration for NCNs
  • Fixed an issue where a PATCH call to BOS v2 components with a filter and non existent component ID would result in 503 and 431 errors
  • Fixed an issue where BOS operators would output errors when all nodes exceed retry limit
  • Fixed an issue where cray-upload-recovery-images fails to upload recovery firmware
  • Fixed an issue where cm health report slingshot refresh command was giving a trace back error
  • Updated documentation for IUF to include rolling reboots after upgrading HSN NIC firmware
  • Updated documentation to provide instructions for creating a new Nexus repository and adding RPMs
  • Updated documentation for CAPMC to warn about URL character limits
  • Fixed an issue where BOS v2 requests for too many nodes from PCS exceeding the URL character limit
  • Updated Nexus export and restore script to add better checks for determining existence of nexus-bak PVC or nexus-backup job
  • Updated documentation for fix_failed_to_start_etcd_on_master to better specify how to add a process
  • Fixed an issue with IUF where process-media/pre-install-check dislikes PDF file
  • Fixed an issue where backup_smd_postgres.sh script is not executable
  • CAST-34869: Fixed an issue where cray-hms-rts-snmp would enter encounter a segmentation fault
  • CAST-34141: Fixed an issue where the QLogic driver would crash the system
  • Fixed an issue where an old version of the spire-agent was loaded into Nexus resulting in failed ARM compute builds

Steps

  1. Preparation
  2. Setup Nexus
  3. Upgrade services
  4. Upload NCN images
  5. Update management node CFS configuration
  6. Update test suite packages
  7. Verification
  8. Take Etcd manual backup
  9. NCN reboot
  10. Complete upgrade

Preparation

  1. Validate CSM health.

    See Validate CSM Health.

    Run the CSM health checks to ensure that everything is working properly before the upgrade starts. After the upgrade is completed, another health check is performed. It is important to know if any problems observed at that time existed prior to the upgrade.

    IMPORTANT: See the CSM Install Validation and Health Checks procedures in the documentation for the CURRENT CSM version on the system. The validation procedures in the CSM documentation are only intended to work with that specific version of CSM.

  2. (ncn-m001#) Start a typescript on ncn-m001 to capture the commands and output from this procedure.

    script -af csm-update.$(date +%Y-%m-%d).txt
    export PS1='\u@\H \D{%Y-%m-%d} \t \w # '
    
  3. Download and extract the CSM v1.5.1 release to ncn-m001.

    See Download and Extract CSM Product Release.

  4. (ncn-m001#) Set CSM_DISTDIR to the directory of the extracted files.

    IMPORTANT: If necessary, change this command to match the actual location of the extracted files.

    export CSM_DISTDIR="$(pwd)/csm-1.5.1"
    echo "${CSM_DISTDIR}"
    
  5. (ncn-m001#) Set CSM_RELEASE_VERSION to the CSM release version.

    export CSM_RELEASE_VERSION="$(${CSM_DISTDIR}/lib/version.sh --version)"
    echo "${CSM_RELEASE_VERSION}"
    
  6. Download and install/upgrade the latest documentation on ncn-m001.

    See Check for Latest Documentation.

Setup Nexus

(ncn-m001#) Run lib/setup-nexus.sh to configure Nexus and upload new CSM RPM repositories, container images, and Helm charts:

cd "$CSM_DISTDIR"
./lib/setup-nexus.sh ; echo "RC=$?"

On success, the output should end with the following:

+ Nexus setup complete
setup-nexus.sh: OK
RC=0

In the event of an error, consult Troubleshoot Nexus to resolve potential problems and then try running setup-nexus.sh again. Note that subsequent runs of setup-nexus.sh may report FAIL when uploading duplicate assets. This is okay as long as setup-nexus.sh outputs setup-nexus.sh: OK and exits with status code 0.

Upgrade services

(ncn-m001#) Run upgrade.sh to deploy upgraded CSM applications and services:

cd "$CSM_DISTDIR"
./upgrade.sh

On success, the output should end with the following:

+ CSM applications and services upgraded
upgrade.sh: OK

Upload NCN images

It is important to upload NCN images to IMS and to edit the cray-product-catalog. This is necessary when updating products with IUF. If this step is skipped, IUF will fail when updating or upgrading products in the future.

(ncn-m001#) Execute script to upload CSM NCN images and update the cray-product-catalog.

/usr/share/doc/csm/upgrade/scripts/upgrade/upload-ncn-images.sh

On success, the output should end with the following:

Uploading Kubernetes images...
Uploading Ceph images...
Updating image ids...

Update management node CFS configuration

This step updates the CFS configuration which is set as the desired configuration for the management nodes (NCNs). It ensures that the CFS configuration layers reference the correct commit hash for the version of CSM being installed. It then waits for the components to reach a configured state in CFS.

  1. (ncn-m001#)

    cd "$CSM_DISTDIR"
    ./update-mgmt-ncn-cfs-config.sh --base-query role=management \
       --save --create-backups --clear-error
    

    The output will look similar to the truncated output shown below.

    INFO: Querying CFS configurations for the following NCNs: x3000c0s5b0n0, ...
    INFO: Found configuration "management-csm-1.5.0" for component x3000c0s5b0n0
    ...
    INFO: Updating existing layer with repo path /vcs/cray/csm-config-management.git and playbook ncn_nodes.yml
    INFO: Property "commit" of layer with repo path /vcs/cray/csm-config-management.git and playbook ncn_nodes.yml updated ...
    INFO: Property "name" of layer with repo path /vcs/cray/csm-config-management.git and playbook ncn_nodes.yml updated ...
    INFO: No layer with repo path /vcs/cray/csm-config-management.git and playbook ncn-initrd.yml found.
    INFO: Adding a layer with repo path /vcs/cray/csm-config-management.git and playbook ncn-initrd.yml to the end.
    INFO: Successfully saved CFS configuration "management-csm-1.5.0-backup-20240410T205149"
    INFO: Successfully saved CFS configuration "management-csm-1.5.0"
    INFO: Successfully saved 1 changed CFS configuration(s) to CFS.
    INFO: Updated 9 CFS components.
    INFO: Waiting for 9 component(s) to finish configuration
    INFO: Summary of number of components in each status: pending: 9
    INFO: Waiting for 9 pending component(s)
    INFO: Sleeping for 30 seconds before checking status of 9 pending component(s).
    ...
    INFO: Sleeping for 30 seconds before checking status of 9 pending component(s).
    INFO: 9 pending components transitioned to status configured: x3000c0s5b0n0, ...
    INFO: Finished waiting for 9 component(s) to finish configuration.
    INFO: Summary of number of components in each status: configured: 9
    ====> Completed update of CFS configuration(s)
    ====> Cleaning up install dependencies
    

    When configuration of all components is successful, the summary line will show all components with status “configured”.

Update test suite packages

(ncn-m001#) Update select RPMs on the NCNs.

/usr/share/doc/csm/upgrade/scripts/upgrade/util/upgrade-test-rpms.sh

On success, the output should end with the following:

Enabling and restarting goss-servers
SUCCESS

Verification

  1. Verify that the new CSM version is in the product catalog.

    (ncn-m001#) Verify that the new CSM version is listed in the output of the following command:

    kubectl get cm cray-product-catalog -n services -o jsonpath='{.data.csm}' | yq r -j - | jq -r 'to_entries[] | .key' | sort -V
    

    Example output that includes the new CSM version (1.5.1):

    0.9.2
    0.9.3
    0.9.4
    0.9.5
    0.9.6
    1.0.1
    1.0.10
    1.2.0
    1.2.1
    1.2.2
    1.3.0
    1.3.1
    1.4.0
    1.4.1
    1.4.2
    1.4.3
    1.4.4
    1.5.0
    1.5.1
    
  2. Confirm that the product catalog has an accurate timestamp for the CSM upgrade.

    (ncn-m001#) Confirm that the import_date reflects the timestamp of the upgrade.

    kubectl get cm cray-product-catalog -n services -o jsonpath='{.data.csm}' | yq r  - '"1.5.1".configuration.import_date'
    

Take Etcd manual backup

(ncn-m001#) Execute the following script to take a manual backup of the Etcd clusters.

/usr/share/doc/csm/scripts/operations/etcd/take-etcd-manual-backups.sh post_patch

These clusters are automatically backed up every 24 hours, but taking a manual backup at this stage in the upgrade enables restoring from backup later in this process if needed.

NCN reboot

This is an optional step but is strongly recommended. As each patch release includes updated container images that may contain CVE fixes, it is recommended to reboot each NCN to refresh cached container images. For detailed instructions on how to gracefully reboot each NCN, refer to Reboot NCNs.

Complete upgrade

(ncn-m001#) Remember to exit the typescript that was started at the beginning of the upgrade.

exit

It is recommended to save the typescript file for later reference.