This document guides an administrator through the upgrade of Cray Systems Management from version 1.5 to version 1.6. This procedure works for all patch versions of the source and target CSM releases.
This procedure is also the correct one to follow in the unusual situation of upgrading from a pre-release version of CSM 1.6.0 to a newer version of CSM 1.6.
When upgrading a system, follow this top-level file from top to bottom. The content on this top-level page is meant to be terse. For additional reference material on the upgrade processes and scripts mentioned explicitly on this page, see resource material.
For systems with only three worker nodes (typically Testing and Development Systems (TDS)), prior to proceeding with this upgrade, CPU limits MUST be
lowered on several services in order for this upgrade to succeed. This step is
executed automatically in the CSM upgrade prerequisites hook executed by IUF before pre-install-check
.
See description of CSM upgrade hooks for more details on this CSM upgrade hook.
See TDS Lower CPU Requests for more information.
Independently, for three-worker systems the customizations.yaml
file is edited automatically during the upgrade, prior to deploying new CSM services. These
settings are contained in /usr/share/doc/csm/upgrade/scripts/upgrade/tds_cpu_requests.yaml
. This file can be modified (prior to proceeding with this
upgrade), if other settings are desired in the customizations.yaml
file for this system.
For more information about modifying customizations.yaml
and tuning for specific systems, see
Post-Install Customizations.
The upgrade to CSM 1.6 is done through IUF. Follow one of the following two procedures:
Important: Take note of the below content for troubleshooting purposes, in the event that issues are encountered during the upgrade process.
General upgrade troubleshooting
If the execution of the upgrade procedure fails, it is safe to rerun the failed script. If a rerun still fails, wait for 10 seconds and then run it again. If the issue persists, then refer to the below troubleshooting procedures.
General Kubernetes troubleshooting
For general Kubernetes commands for troubleshooting, see Kubernetes Troubleshooting Information.
PXE boot troubleshooting
If execution of the upgrade procedures results in NCNs that have errors booting, then refer to the troubleshooting procedures in the PXE Booting Runbook.
NTP troubleshooting
During upgrades, clock skew may occur when rebooting nodes. If one node is rebooted and its clock differs significantly from those that have not been rebooted, it can
cause contention among the other nodes. Waiting for chronyd
to slowly adjust the clocks can resolve intermittent clock skew issues. This can take up to 15 minutes or
longer. If it does not resolve on its own, then follow the Configure NTP on NCNs procedure to troubleshoot it further.
Bare-metal Etcd recovery
During the upgrade process of the master nodes, if it is found that the bare-metal Etcd cluster (that houses values for the Kubernetes cluster) has a failure, it may be necessary to restore that cluster from backup. See Restore Bare-Metal etcd Clusters from an S3 Snapshot for that procedure.
Bare-metal Etcd certificate
After upgrading, apiserver-etcd-client
certificate may need to been renewed. See Kubernetes and Bare Metal EtcD Certificate Renewal
for procedures to check and renew this certificate.
Back-ups for etcd-operator
Clusters
After upgrading, if health checks indicate that Etcd pods are not in a healthy/running state, recovery procedures may be needed. See
Backups for etcd-operator
Clusters for these procedures.
Recovering from Postgres database issues
After upgrading, if health checks indicate the Postgres pods are not in a healthy/running state, recovery procedures may be needed. See Troubleshoot Postgres Database for troubleshooting and recovery procedures.
Back-ups for Postgres databases
After upgrading, if any *postgresql-db-backup
cronjob pods are in error, see NCN Resource Checks.
If the most recent *postgresql-db-backup
cronjob pod is in error and the pod log indicates a failure
due to pg_dumpall: error: pg_dump failed on database ...
, contact support to further investigate and resolve.
Troubleshooting Spire pods not starting on NCNs
Troubleshoot SLS not working
Rerun a step
When running master node and storage node upgrade scripts, each script records what has been done successfully on a node. This is recorded in the
/etc/cray/upgrade/csm/{CSM_VERSION}/{NAME_OF_NODE}/state
file.
If a rerun is required, the recorded steps to be re-run must be removed from this file.
(ncn#
) Here is an example of state file of ncn-m001
:
cat /etc/cray/upgrade/csm/csm-{CSM_VERSION}/ncn-m001/state
Example output:
[2021-07-22 20:05:27] UNTAR_CSM_TARBALL_FILE
[2021-07-22 20:05:30] INSTALL_CSI
[2021-07-22 20:05:30] INSTALL_WAR_DOC
[2021-07-22 20:13:15] SETUP_NEXUS
[2021-07-22 20:13:16] UPGRADE_BSS <=== Remove this line if you want to rerun this step
[2021-07-22 20:16:30] CHECK_CLOUD_INIT_PREREQ
[2021-07-22 20:19:17] APPLY_POD_PRIORITY
[2021-07-22 20:19:38] UPDATE_BSS_CLOUD_INIT_RECORDS
[2021-07-22 20:19:38] UPDATE_CRAY_DHCP_KEA_TRAFFIC_POLICY
[2021-07-22 20:21:03] UPLOAD_NEW_NCN_IMAGE
[2021-07-22 20:21:03] EXPORT_GLOBAL_ENV
[2021-07-22 20:50:36] PREFLIGHT_CHECK
[2021-07-22 20:50:38] UNINSTALL_CONMAN
[2021-07-22 20:58:39] INSTALL_NEW_CONSOLE
Skip a step after running it manually
When running master node and storage node upgrade scripts, each script records what has been done successfully on a node. This is recorded in the
/etc/cray/upgrade/csm/{CSM_VERSION}/{NAME_OF_NODE}/state
file.
If a step fails in the upgrade script and then is successfully run manually, this step needs to be added to the state file so it will be skipped by the upgrade procedure.
(ncn#
) Here is an example of state file of ncn-m001
:
cat /etc/cray/upgrade/csm/csm-{CSM_VERSION}/ncn-m001/state
Example output:
[2021-07-22 20:05:27] UNTAR_CSM_TARBALL_FILE
[2021-07-22 20:05:30] INSTALL_CSI
[2021-07-22 20:05:30] INSTALL_WAR_DOC
[2021-07-22 20:13:15] SETUP_NEXUS
[2021-07-22 20:13:16] UPGRADE_BSS
[2021-07-22 20:16:30] CHECK_CLOUD_INIT_PREREQ
[2021-07-22 20:19:17] APPLY_POD_PRIORITY
[2021-07-22 20:19:38] UPDATE_BSS_CLOUD_INIT_RECORDS
[2021-07-22 20:19:38] UPDATE_CRAY_DHCP_KEA_TRAFFIC_POLICY
[2021-07-22 20:21:03] UPLOAD_NEW_NCN_IMAGE
[2021-07-22 20:21:03] EXPORT_GLOBAL_ENV
[2021-07-22 20:50:36] PREFLIGHT_CHECK
[2021-07-22 20:50:38] UNINSTALL_CONMAN
[2021-07-22 20:58:39] INSTALL_NEW_CONSOLE <=== Add this line if this has been manually run and should be skipped
Helm chart timeouts
See Helm Chart Timeouts
known issues for steps to increase the timeout for a chart that is taking longer than five minutes to deploy.
rsync
error
When executing command /usr/share/doc/csm/upgrade/scripts/upgrade/prerequisites.sh --csm-version ${CSM_RELEASE}
, if rsync
error is displayed in console after stage REPAIR_AND_VERIFY_CHRONY_CONFIG
or in
output.log
as shown in example below, then ensure latest version of libcsm
and docs-csm
RPMs are successfully installed and then re-execute the same command.
/usr/share/doc/csm/upgrade/scripts/upgrade/prerequisites.sh --csm-version ${CSM_RELEASE}
...
====> REPAIR_AND_VERIFY_CHRONY_CONFIG ...
[ERROR] - Unexpected errors, check logs: /root/output.log
Example output.log
:
====> REPAIR_AND_VERIFY_CHRONY_CONFIG ...
rsync: [sender] link_stat "/etc/cray/upgrade/csm/csm-<version>/tarball/csm-<version>/chrony" failed:
No such file or directory (2)
rsync error: some files/attrs were not transferred (see previous errors) (code <number>) at main.c(<line number>)
[sender=<version>]
<line number> /usr/share/doc/csm/upgrade/scripts/upgrade/prerequisites.sh
rsync -aq "${CSM_ARTI_DIR}"/chrony "${target_ncn}":/srv/cray/scripts/common/